ATM PVC Configuration
Field Action Default
VPI
Enter a VPI value
1
between 0 and 255.
0
VCI
Enter a VPI value
1
between 32 and 65535.
35
Service Category
Select the type of service adapter to the traffic
from the scroll down list:
UBR without PCR : Unspecified Bit Rate
UBR with PCR : Unspecified Bit Rate
CBR : Constant Bit Rate
Non Realtime VBR : Variable Bit Rate
Realtime VBR : Variable Bit Rate
UBR
without
PCR
Peak Cell Rate
2
Enter a maximum number of cells transmitted
per second, between 1 and 2491.
0
Sustainable Cell Rate
3
Enter an average number of cells transmitted
per second.
Note: This number must be lower than the
Peak Cell Rate (PCR).
0
Maximum Burst Size
3
Enter the maximum number of cells emitted in
burst (value between 1 and 1000 000).
0
Enable Quality Of Service
Field Action Default
Enable Quality Of Service
Check the box to activate the quality of
service and display the new "Quality of
Service" menu in the Advanced Setup
section.
Not checked
1
This value is delivered to you by your Internet Service Provider (ISP).
2
This field only appears when the "UBR with PCR", "CBR", "Non Realtime VBR" or "Realtime VBR" type of
service is selected.
3