User's Manual

Table Of Contents
s
E
Ref. : SCT TMO LOG SPEC
163
Revision : B
Sec. Ref. :
Date : 2003-01-22
E. CONFIDENTIAL All rights of reproduction and disclosure reserved.
Page 25 / 52
!
High
: High priority
!
Normal
: Normal priority
!
Low
: Low priority
MEAN
: granted mean throughput.
100 to 50 000 000 bytes/hour
PEAK
: peak throughput.
1000 to 256 000 bytes/s
2.5.3 Data Transfer Info
These screen give information about the current data transfer.
2.5.3.1 Data Transfer 1
st
Screen
TS
: below the TS label is displayed the Timeslot Allocation Type:
!
Dyn
: Dynamic allocation
!
Fix
: Fixed allocation
!
No
: No allocation
on the right side of the TS label are displayed the Uplink and Downlink timeslot allocation
!
UL
: Uplink Timeslot allocation. A dash (“
-
“) indicates an unallocated timeslot, a digit indicates an
allocated timeslot (and also indicates its timeslot number)
!
DL
: Downlink Timeslot allocation. A dash (“
-
“) indicates an unallocated timeslot, a digit indicates an
allocated timeslot (and also indicates its timeslot number)
HeaC
: SNDCP Header Compression
!
Y
: SNDCP Header Compression used
!
N
: SNDCP Header Compression not used
DatC
: SNDCP Data Compression
!
Y
: SNDCP Data Compression used
!
N
: SNDCP Data Compression not used
CS
: Coding Scheme.
1
to
4
!
UL
: Uplink Coding Scheme
!
DL
: Downlink Coding Scheme
TFI