User's Manual
Table Of Contents
- OBJECT
- TRACE FUNCTIONS
- TRACE MENU
- UPDATE OF THE TRACED INFORMATION
- MS INFO
- NETWORK
- SERVING CELL Main screen in IDLE mode
- SERVING CELL Second screen in IDLE mode
- NEIGHBOURING CELL Main screen in IDLE mode
- NEIGHBOURING CELL Second screen in IDLE mode
- SERVING CELL screen in DEDICATED mode
- NEIGHBOURING CELL screen in DEDICATED mode
- SERVING CELL Main screen in PBCCH mode
- SERVING CELL Second screen in PBCCH mode
- NEIGHBOURING CELL first screen in PBCCH mode
- NEIGHBOURING CELL Second screen in PBCCH mode
- TCH Hopping features in Dedicated mode
- PBCCH frequency screens in PBCCH mode with hopping
- PBCCH frequency screens without hopping
- Network summary screen
- GPRS INFO
- SIM INFO
- FORCING FUNCTIONS
- BCCH SCANNING
- QOS INFO
- SERIAL LINK SETUP
- RF SCANNING IN PROGRESS SCREEN
- SWITCHING BETWEEN WAP BROWSER AND TRACE SCREENS
- ANNEX: GPRS QOS PARAMETERS DEFINITION
s
E
Ref. : SCT TMO LOG SPEC
163
Revision : B
Sec. Ref. :
Date : 2003-01-22
E. CONFIDENTIAL All rights of reproduction and disclosure reserved.
Page 11 / 52
-
cd/md
Downlink signalling counter indicator with :
cd : current downlink signalling counter
md : maximum downlink signalling counter
- RX : -110 to -11 dBm
Current value of RX_LEV_SERVING_CELL for the BCCH of the serving cell.
- C1 : -92 to 127
Current value of the criterion C1 for the serving cell.
- C2 : -92 to 127
Current value of the cell reselection criterion C2 for the serving cell if the
network allows to calculate it.
- RM : -110 to -46 dBm
Current value of RX_LEV_ACCES_MIN for the serving cell in dBm.
- CI : abcde
Current value of the CI (Cell Identity) on 4 hexadecimal digits.
- LAI : abc de fghij
Current value of the Location Area Identity:
abc
Country code on 3 digits (MCC).
de
Operator code on 2 digits (MNC).
fghij
Location area code on 5 decimal digits (LAC).
2.4.2 SERVING CELL Second screen in IDLE mode
This screen gives additional GSM Cell Reselection information along with information about the GPRS
capability of the Serving Cell:
- CRH: 0 to 14 dB, 2 dB steps
Current value of CELL RESELECT HYSTERESIS for the Serving cell
- CRO: 0 to 126 dB, 2 dB steps
Current value of CELL RESELECT OFFSET for the Serving cell
- PY: 20 to 620 s, 20 s steps. None
if no Temporary Offset is used
Current value of PENALTY TIME for the Serving Cell.
- TMP: 0 to 60 dB, 10 dB steps. Inf
for Infinite Temporary Offset
Current value of TEMPORARY OFFSET for the Serving Cell
- GPRS: Yes or No
Indicates whether the Serving Cell supports GPRS or not
- RA COL: 0 to 7
Current value of RA Colour for the Serving Cell (only valid if the Serving Cell supports GPRS)