Setting the key app/tamper alarm/level to an appropriate value configure
tamper switch management feature.
Tamper Alarm Level
app/tamper alarm/level
0 No Alarm.
1 Send Alarm (No Sound Alarm).
2 Send Alarm and Activates Buzzer (Sound Alarm)
0 (0 – 2)
The key app/failure ID/alarm ID defines the value of the alarm ID to send
in Wiegand or DataClock. This ID permits to distinguish between a user ID
and an error ID. To be validated, key app/failure ID/enabled must be set to
1.
Tamper Alarm ID
app/failure ID/alarm ID
app/failure ID/enabled
65535 (0 – 65535)
1
In Wiegand and DataClock the alarm ID is sent like other Failure Ids. See
the documentation MorphoAccess™ Remote Messages Specification for a
description of the packet format in UDP and RS485.
E
E
x
x
a
a
m
m
p
p
l
l
e
e
s
s
Example 1: Send an alarm ID (62221) in Wiegand, and play sound
warning, in case of intrusion detection.
To send an alarm in Wiegand, the key app/send ID wiegand/enabled must
be set to 1, and the key app/tamper alarm/level must be set to 2 (alarm
and buzzer.)
The key app/failure ID/alarm ID must be set to 62221 to link the intrusion
event to this identifier.
Example 2: Send an alarm in UDP quietly in case of intrusion detection.
To send an alarm in UDP, the key app/send ID UDP/enabled must be set
to 1.
Then the key app/tamper alarm/level must be set to 1 (quiet alarm.)