Installation Guide
Table Of Contents
- MA500 Series
- INTRODUCTION
- SAFETY INSTRUCTIONS
- GENERAL DESCRIPTION
- MA5XX VERSIONS INSTALLATION PROCEDURE
- OMA5XX VERSIONS INSTALLATION PROCEDURE
- ELECTRICAL INTERFACE
- USER INTERFACE
- MORPHOACCESSTM MA5XX SERIES TECHNICAL CHARACTERISTICS
- Recommendations
- APPENDIX 1 - FINGERPRINT PLACEMENT RULES
- APPENDIX 2 – RELATED DOCUMENTS
- APPENDIX 3 - DRILLING TEMPLATE
- SUPPORT
S
S
A
A
F
F
E
E
T
T
Y
Y
I
I
N
N
S
S
T
T
R
R
U
U
C
C
T
T
I
I
O
O
N
N
S
S
The installation of this product should be made by a qualified service
technician and should conform to all local codes.
It is strongly recommended that a class II power supply at 12 V ±5% and
0.75 A. min be used in accordance with Safety Electrical Low Voltage
(SELV) parameters. The 12 V power supply cable length should not
exceed 5 meters.
This product may be installed with a power supply conforming to
EN60950, in accordance with the NEC Class 2 requirements; or supplied
by a listed EN60950 external Power Unit marked Class 2, Limited Power
source, or LPS and rated 12 V DC, 0.75 A minimum.
In case of “Power Over Ethernet” use, the POE hub or switch features has
to be conformed with IEEE 802.3-af standard. An insulation greater than
2000V is provided between MA5xx terminal and Ethernet network.
In case of building to building connection it is recommended to connect 0V
to ground. This ground (ground security reference) cable must be
connected with the terminal block board fixation screw marked with the
universal ground symbol ( see p16 ).
E
E
u
u
r
r
o
o
p
p
e
e
i
i
n
n
f
f
o
o
r
r
m
m
a
a
t
t
i
i
o
o
n
n
:
:
SAGEM hereby declares that the SAGEM MorphoAccess™ has been
tested and found compliant with the following listed standards as required
by the EMC Directive 89/336/EEC: EN55022 (1994) / EN55024 (1998),
EN300-330 (1999) and by the low voltage Directive 73/23/EEC amended
by 93/68/EEC: EN60950 (2000).
Caution: The MA500 terminal is a Class A device. In a residential
environment, this device may cause interference. In this case, the user is
encouraged to try to correct the interference with appropriated measures
such as :
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
6
SAGEM Sécurité document. Reproduction and disclosure forbidden. SK-53018-03