Installation Guide
Table Of Contents
- MA500 Series
- INTRODUCTION
- SAFETY INSTRUCTIONS
- GENERAL DESCRIPTION
- MA5XX VERSIONS INSTALLATION PROCEDURE
- OMA5XX VERSIONS INSTALLATION PROCEDURE
- ELECTRICAL INTERFACE
- USER INTERFACE
- MORPHOACCESSTM MA5XX SERIES TECHNICAL CHARACTERISTICS
- Recommendations
- APPENDIX 1 - FINGERPRINT PLACEMENT RULES
- APPENDIX 2 – RELATED DOCUMENTS
- APPENDIX 3 - DRILLING TEMPLATE
- SUPPORT
P
P
o
o
w
w
e
e
r
r
s
s
u
u
p
p
p
p
l
l
y
y
9 to 16 Volts ± 5% and 1,5A peak power supply
Cable cross section depends on the length 0. 75mm
2
recommended.
Consumption : 750mA maximum rms @12V ( < 1,5 A peak )
350mA typical rms @12V
Power Over Ethernet compatibility ( IEEE802.3 af ) :
Class 0 or Class 3 hub/switch equipment mandatory ( 15,4W )
MA5xx configurations
POE Alternative A compliant with RJ45 and terminal blocks
POE Alternative B compliant with RJ45 only
OMA5xx configuration
POE Alternative A compliant only
“POE Alternative A” means power on data lines : Only 2 pairs are
needed.
“POE Alternative B” means power on 2 extra pairs lines : 4 pairs are
required.
S
S
i
i
z
z
e
e
a
a
n
n
d
d
w
w
e
e
i
i
g
g
h
h
t
t
MA5xx version 160 x 145 x 75 mm
0,800 Kg
OMA5xx version 289 x 218 x 99 mm
2 Kg
SK-53018-03 SAGEM Sécurité document. Reproduction and disclosure forbidden.
27