User's Manual
SE32/03-011145-01 SAGEM SA document. Reproduction and disclosure forbidden. 65
E
S
When using the Deister contacless card reader, COM1 parameters
should be:
Setting up COM2 port
To activate this port, press the CONFIG key to access the
configuration files. Press the NEXT key until the file menu shows
"/cfg/Maccess". Press the EDIT key, and select the RS232 section.
The values are:
Baudrate
Databits
Stopbits
Parity
Flow ctrl
3 (9600)
8
1
0
0
Parameters Value Comment
Send 0 (default value) The RS232 output is not
activated.
1 The RS232 output is acti-
vated.
Format 0 (default value) The ID is sent in ASCII for-
mat.
1 The ID is sent in Hexa for-
mat.
2 The ID is sent is BCD
(1)
format.
(1)
BCD: Binary Code Decimal
PREV NEXT EDITEXIT
FILE: cfg/Maccess
SECTION: COM2