ANNEXE 1 : Reference sensitivity level
The min reference guaranteed sensitivity is:
The sensitivity level is defined as the input level for which class II bits RBER/FER don’t exceed 2.4%
This minimum sensitivity shall be :
GSM 900 MS: -105 dBm max
DCS 1800 MS: -105 dBm max
Notes :
This min sensitivity value is guaranteed at 25°C and under static conditions.
Test Conditions :
Measurement is performed with :
A flexible coaxial cable equipped with a GSC connector.
A SMA-FSC adapter
A GSM tester
GSM testor
GSC Cable + SMA-FSC Adapter
RF output Murata GSC
connector
Module
Faraday Chamber