User's Manual
s
e
Centre de Saint Christophe - URD 37
TELEPHONIE MOBILE
MOBILE PHONES
Ref. : SCT TMO MASV2 SPEC 14 M
Date : 04/03/03
E All rights reserved. Reproduction and disclosure prohibited Page 36
MO130 module for mobile applications
This document contains information on a product under development. SAGEM reserves the right to change or discontinue this product
without notice.
NB: a battery level measurement algorithm is turning the module OFF when VBAT < 3.45V for more than a
few minutes.
6.2 POWER SUPPLIES
6.2.1 VRDBB (120 pin connector, pin 3)
Signal Min Typ Max Remarks
Voltage level 1.65V 1.80V 1.95V
Current capability
Active mode
- - 10mA
Current capability
Sleep mode
- - 1mA
Quiescent current
Active mode
-
150µA
-
Quiescent current
Sleep mode
-
20µA
-
Quiescent current
Disable
-
1µA
-
Rise time -
10µs
-
Protection
6.2.2 VRIO (120 pin connector, pin 2)
Signal Min Typ Max Remarks
Voltage level 2.70V 2.80V 2.90V
Current capability
Active mode
- - 10mA
Current capability
Sleep mode
- - 1mA
Quiescent current
Active mode
-
150µA
-
Quiescent current
Sleep mode
-
20µA
-
Quiescent current
Disable
-
1µA
-
Rise time -
10µs
-
Protection
6.2.3 V56 (120 pin connector, pin 74)
Signal Min Max Remarks
Voltage level 5.5V 5.7V
Current capability - 27mA
Rise time - 2ms
Protection
Un-regulated
NB: in OFF mode, this power supply is in low power configuration (V56 = 4.5V and I
V56