PROBLEM POSSIBLE CAUSES EASY SOLUTION
Espresso runs
out too quickly.
Coee is ground too coarsely. Use slightly ner grind.
Refer to ‘Setting the Grind Size’, page 10
and ‘Under Extraction’, page 13.
Not enough coee in the
lter basket.
Increase dose of coee.
Refer to ‘Dosing’, page 10 and ‘Under
Extraction’, page 13. Tamp then use the
Razor
™
dose trimming tool to trim o
excess coee.
Coee tamped too lightly. Tamp between or 15–20kg of pressure.
Espresso runs out
around the edge
of the portalter.
Portalter not inserted
in the group head correctly.
Ensure portalter is completely inserted
and rotated until resistance is felt.
There are coee grounds
around the lter basket rim.
Clean excess coee from the rim of the
lter basket to ensure a proper seal in
group head.
Too much coee in the
lter basket.
Lower dose of coee.
Refer to ‘Dosing’, page 10. After tamping,
trim the coee dose using the Razor
™
dose trimming tool.
The silicone seal surrounding
the shower screen needs to be
replaced to ensure the portaler
is properly secured into the
group head.
Refer to ‘Replacing the Silicone Seal’,
page 17.
No steam.
Machine has not reached
operating temperature.
Allow time for the machine to reach
operating temperature.
Water tank is empty. Fill tank.
Water tank is not fully inserted
and locked into position.
Push water tank down completely
to lock into place.
Machine needs to be
decalcied.
Perform descale cycle.
Steam wand is blocked. Refer to ‘Cleaning the Steam Wand’,
page 16.
Pulsing / pumping
sound while
extracting espresso
or steaming milk.
The machine is carrying out the
normal operation of the pump.
No action required as this is the normal
operation of the machine.
Water tank is empty. Fill tank.
Water tank is not fully inserted
and locked into position.
Push water tank down completely
to lock into place.