EXTRACTING ESPRESSO
As a guide the espresso will start to ow after
8–12 seconds (infusion time) and should be
the consistency of dripping honey.
If the espresso starts to ow after less than
6 seconds, you have either under dosed the
lter basket and /or the grind is too coarse.
This is an UNDER EXTRACTED shot.
If the espresso starts to drip but doesn’t ow
after 15 seconds, the grind is too ne. This is
an OVER EXTRACTED shot.


Press the 1 Cup button for less than 1 second,
the button will ash indicating that it has been
selected. A preset single espresso volume
of approximately 30ml will be extracted. The
machine will automatically stop once the
pre-set volume has been extracted.


Press the 2 Cup button for less than a second,
the button will ash indicating that it has been
selected. A preset double espresso volume
of approximately 60ml will be extracted. The
machine will automatically stop once the
pre-set volume has been extracted.
NOTE
Pressing the corresponding 1 Cup or 2 Cup
button during the programmed espresso
extraction will immediately stop the
extraction.
PROGRAMMING COFFEE VOLUME
Press and hold the 1 Cup and 2 Cup buttons
for 2 seconds, the buttons will illuminate
and ash.
2s
+
+
OFF
To set the 1 Cup volume:
Press the 1 Cup button for about 3 seconds
to start the extraction.
Press the 1 Cup button again to stop the
extraction. The modied volume will be
saved.
To set the 2 Cup volume, follow the above
steps and select the 2 Cup button to start
and stop the extraction.
NOTES
If no user input after 30 seconds. Machine
returns to ‘ready mode’
The modied coee volume will be saved
into memory for the next use or when the
machine is re-started.
Pressing the steam or hot water button at
any stage will cancel the operation and the
machine will return to ready mode without
saving any coee volume program.

VOLUME
Press and hold the 1 Cup or 2 Cup button for
more than a second. After one second the
pump will start at pre-infusion pressure and
continue while button is pressed. Release
the button to start the extraction. Press any