Datasheet
LS 17500
Storage
•
The storage area should be
clean, cool (preferably not
exceeding + 30°C), dry and
ventilated.
Warning
•
Fire, explosion and burn hazard.
•
Do not recharge, short circuit,
crush, disassemble, heat above
100°C (212°F), incinerate, or
expose contents to water.
•
Do not solder directly to the cell
(use tabbed cell versions instead).
Ø 5.5 max
(flat area)
1.35 ± 0.3
50.5 ± 0.4
0.4 ± 0.1
Ø 7.5 ± 0.1
Ø 16.94 ±
0.19
Dimensions in mm.
Capacity (Ah)
Current (mA)
Restored Capacity versus Current and Temperature (2.0 V cut-off)
Cell voltage (V)
Time (hours)
Typical discharge profiles at + 20°C
Current (mA)
Cell voltage (V)
Voltage plateau versus Current and Temperature (at mid-discharge)
Saft
Specialty Battery Group
12, rue Sadi Carnot
93170 Bagnolet - France
Tel.: +33 (0)1 49 93 19 18
Fax : +33 (0)1 49 93 19 69
www.saftbatteries.com
Doc. N
o
31029-2-0710
Information in this document is subject to change without notice
and becomes contractual only after written confirmation by Saft.
For more details on primary lithium technologies please refer to
Primary Lithium Batteries Selector Guide Doc N
o
31048-2.
Published by the Communications Department.
Photo credit: Saft
Société anonyme au capital de 31 944 000
RCS Bobigny B 383 703 873