Installation guide

RouteRecorder® 4C Installation Guide July 2009
ROUTERECORDER 4C IG Ver 1.3.docx 19
Appendix C: System Health Logs
Each health log displays the date in MM.DD.YY format, the time in 24-hour format, the IP address of the MDVR, and the
log name, in that order. The following table lists all log names and the information that appears after them.
Log Name Meaning Parameter reported
SYSTEM INFORMATION System operating normal p1: Degrees Celsius of
processor
p2: Input voltage in millivolts
SYSTEM UNDER
VOLTAGE
Low input voltage going below
9v threshold and when it
comes above 10v
p1: Not used
p2: Voltage value causing error
CAMERA INPUT ERROR Video signal not present on
channel
p1: Camera ID
p2: Not used
Trigger Name User configured trigger name
is reported at each state
change
NONE USED
ACCX Acceleration trigger activated p1: Not used
p2: Acceleration value x1000
ACCY Acceleration trigger activated p1: Not used
p2: Acceleration value x1000
SPD Speed trigger set p1: Not used
p2: Speed value
POWER ON START Unit has booted None
IGN Ignition trigger state None
MEDIA_READ_ERROR Reading from media storage
device failed
None
MEDIA_WRITE_ERROR Writing to media storage
device failed
None