HUGO User Manual

HUGO-X1 User Manual
www.safeguardpowersolutions.com 855.484.6797 P a g e | 8
7. Double check wiring to ensure the connection is correct, close and lock the side panel
as shown below.
8. Finally, connect HUGO’s power cord with the main power outlet. NOTE: HUGO’s rated
input and output is 115 volts, can be fitted to any circuit breaker rated 15A. Ensure all
connects are correct and that the input and output power cord is properly grounded.
9. Turn the front door cam to “OPEN” and using the supplied KEY turn the lock counter-
clockwise to open the front door.
10. If HUGO-X1 is used for tankless water heaters and the flow sensor is installed, then
plug in “temp.flow” port in front of the UPS panel. Otherwise, leave this port
unplugged.
11. Turn the HUGO-X1 on via the toggle switch on the left side of the inverter panel. Once
turned on, the unit shall chirp once and the indicator lamp “LINE” will stay lit if utility
power is normal.
12. Indicator lamps on the front panel will display the operational status of the HUGO-X1
as shown in Table 1 above. The HUGO-X1 is also equipped with chirping alerts as