During a power outage or when the main power is below 92v or above 138v, the UPS will transfer to
inverter mode. While in inverter mode, the UPS will monitor flow and temperature sensor (if
purchased separately). When flow sensor detects a demand for water, it will allow power output to
downstream application. When the temperature senses 37deg f (+/- 2 deg f) or below, it will also
override the UPS to turn on. For non-flow applications, unplug (temp.flow) port in front of inverter to
allow flow sensing bypass. For this setup, whenever main power is lost, inverter mode will be in effect
and provide constant power to downstream application.
6. INSTALLATION AND OPERATION
a) FRONT PANEL OF UPS
1.
DC input connector bar (Connected to the battery)
2.
Toggle power switch
3.
Temperature dry contact*
4.
Flow dry contact*
5.
Input/output socket
6.
Indicator lamp
Note that when the toggle power switch is in the “ON” position, voltage may still be present at
the DC output terminals even when the input terminals are disconnected from power. DO
NOT transport or attempt to make connections to the terminals when the toggle switch is in
the “ON” position.
*Disconnected by default, connect for flow sensor installation only.