HUGO User Manual
HUGO-X1 User Manual
www.safeguardpowersolutions.com 855.484.6797 P a g e | 4
• Once the battery has reached the end of its life, properly dispose of the battery. REFER TO YOUR LOCAL
LAWS AND REGULATIONS FOR BATTERY DISPOSAL REQUIREMENTS.
• DO NOT alter the system in any way.
2. INTRODUCTION
The HUGO-X1 is a 350W interruptible power supply (UPS) that is designed to support gas tankless
water heaters, direct vents space heaters, vent free space heaters or any gas-ignited appliance. May
be installed indoors or outdoors.
3. Packing List:
a) HUGO Power Supply
b) Flow Sensor, if purchased separately
c) Hanging brackets (4)
d) Hanging bracket screws (12)
e) User Manual (1)
f) Adhesive Indication Stickers (2)
4. KEY FEATURES
Low output harmonic
The output wave form is pure sine-wave, the harmonic is low
Intelligent MCU Technology
The intelligent MCU (Micro-Computing Unit) can automatically monitor the input voltage surge,
sags, break, output loads and battery status, providing the downstream application with
protections.
High Reliability
The UPS constantly monitors input voltage for surge, sags, or breaks, whenever such occurs, the
UPS will transfer to battery mode within 10ms. It will also constantly monitor output load to
prevent over-load and provide LED indications and chirp sequence alarm to alert user of such
event. The UPS is also built with self-protect and self-reset functions.
DC Start and re-Startup
The UPS is capable to switch on from the battery mode without city power, it will also automatically
re-start when the city power source is back to normal.
Green Power
This series is equipped with high efficiency, EMC standard meet A class, it meets green power
standard.
5. WORKING PRINCIPLE
When the main power is normal, the UPS will transfer the main power to downstream application.