HUGO User Manual
HUGO-X1 User Manual
www.safeguardpowersolutions.com 855.484.6797 P a g e | 12
light and note the chirping sequence, then report this information back to point of
purchase or consult with the manufacture.
b) Troubleshooting
Scenario: The unit does not operate in battery mode.
Possible Cause and Solution:
• Flow sensor installed: If the flow sensor is installed, the UPS will
ONLY operate when it detects cold-water flow. Turn on any faucet
and check the operating status of the UPS. If problem persists,
unplug the “temp.flow” port in front of the UPS panel to bypass the
flow sensing loop. Once unplugged, if the UPS’s operation is
normal under battery mode, then contact point of purchase to
replace the flow sensor. If problem persists, call the manufacture
at 855.484.6797.
• Battery low voltage: Charge up the battery for a full 20 hours. If
problem persists, replace the battery. Battery can be purchased
off-the-shelf, 12V, 35Ah, sealed lead-acid battery.
• Output overload: Remove the appliance connected to the UPS,
wait for 5 minutes. Double check the connected appliance is rated
under 350W. Plug the appliance back into the UPS. Turn on the UPS.
• Output short circuit: Contact point of purchase or the
manufacture for inverter replacement if under warranty.