User manual

Page 50 User manual P1 Audio Processor
Fault finding
Problem : Green Power LED does not light when unit is connected to
the power source.
Checks : Is there any visible or audible sign of physical damage to
the unit? If so, immediately disconnect the unit from the
mains supply and connect Safe Sound Audio for
assistance.
Is the power socket actually switched on?
Is the power source the same voltage as indicated on the
unit’s rear panel?
(NOTE: a 240V AC supply is suitable for powering a unit
marked for 230V AC)
After disconnecting the unit from the mains supply,
check both the mains plug fuse and the rear panel fuse. If
either of these has blown then replace with the correct
type of fuse and then reconnect the unit to the mains
power supply.
If the green power LED still does not light disconnect the
unit from the mains supply and contact Safe Sound Audio
for assistance.
Problem : I have read the user manual but I am still unsure which
type of cable to connect the P1 to my recording device.
Advice : First you need to establish whether your recording device
uses unbalanced or balanced audio connections. Then try
buying the recommended ‘off the shelf’ cable type
recommend in this user manual.
If you are still having problems then contact us for further
advice, preferably by e-mail telling us the make and model
of recording device you are using.