User guide

© SAF Tehnika JSC
Ver. 1.3, 2012 March
CFIP PhoeniX series
Hybrid split mount system
Network Management
SNMP Supports management via SNMP protocol
(supports SNMP v1, v2 and v3 specifications)
GUI and CLI Supports an onboard web-browser based GUI for control/status/provisioning, and
menu-driven Command Line Interface (CLI).
Connector 10/100Base-TX (RJ-45)
Voice Orderwire RJ-45 for PTT handset. We recommend using the Walker PTT-K Series w/EM-95
Transmitter Type.
Alarm Port 2 Form C (SPDT), 2 TTL Output, 4 TTL Input, DB-15HD
Auxiliary Data RS422 via RJ-45; 64 kbps
Environmental requirements/Power
IDU Temperature -5º
to +55º C
IDU Humidity 0 to 95%, non-condensing
Altitude 4570 meters maximum (above sea level)
DC Power -48 Volts ±10%, min. 90 W
Mechanical/Dimensions
IDU Size (WxHxD) 445x44.5x238.5 mm
IDU Weight 3.4 kg
IDU Mounting/Installation
EIA Rack Mount 48.2 cm (19 inch), 1 rack unit (1U)
Overall configuration:
All 1+0 IDUs have: 1xManagement Board & 1xPSU & 1xmodem/IF
All 1+1 IDUs have: 2xManagement Board & 2xPSU & 2xmodem/IF
CFIP PhoeniX M: Modular IDU
Any STM-1 may have Electrical or Optical interface
Enhanced IDU supports up to 63xE1 mux/demux via STM-1