Technical Specifications
Saf-T Vent
®
EZ Seal
SINGLE WALL AL 29-4C
®
SPECIAL GAS VENT
16
5 Ft. Length — Install vent with a continuous pitch of 1/4” per foot, sloping upward toward the
termination, draining back toward the appliance or inline drain. It is important to provide adequate support to
a Saf-T Vent EZ Seal system. Support horizontal portions of the vent system at 6-foot intervals. Vertical
sections should be supported at least every 30-feet and after every offset or transition.
Straight Lengths:
Part Number DIM - A DIM - B DIM - C
Nominal Diameter Installed Length Maximum OD
9360 3 59.5 3.4
9460 4 59.5 4.4
4 Ft. Length — Install vent with a continuous pitch of 1/4” per foot, sloping upward toward the termination, draining
back toward the appliance or inline drain. It is important to provide adequate support to a Saf-T Vent EZ Seal system. Support
horizontal portions of the vent system at 6-foot intervals. Vertical sections should be supported at least every 30-feet and after
every offset or transition.
Part Number DIM - A DIM - B DIM - C
Nominal Diameter Installed Length Maximum OD
9308 3 46 3.4
9408 4 46 4.4
9508 5 46.5 5.4
9608 6 46.5 6.4
9708 7 46.5 7.4
9808 8 46.5 8.4
9908 9 46.5 9.4
91008 10 46.5 10.4
91208 12 46 12.4
91408 14 46 14.4
91608 16 46 16.4
C
A
B