Specifications
Saeco International Group Rev. 3 / Jan. 2009 Page 1 / 2
TALEA / ODEA - LINE 06 STANDARD CONTROLS
6.2. Service plan
Action
1 Visual check (transport damage)
2 Recording the appliance data
3 Functional check / fault analysis
4 Opening the appliance
5 Visual check (leaks)
6 Checking the mechanical procedure (functional test)
7 Repairing the faults occurred
8 Checking the modifi cations
9 Service activities according to the Service plan
10 Cleaning inside
11 Functional test (when the appliance is open / leak test)
12 Assembly
13 End test according to the Test plan
14 Let steam out (Winter)
15 Exterior cleaning
16 Lubricating the brewing unit
17 Insulation test HG 701
18 Documentation
Parts Action Resources
Water fi lter C/R
Lip seal / water tank R
Cream valve C
Valve spring R
O ring valve pin R
O ring valve pin R
Sieve (brewing unit) C/VC Fat solvent
Hose connections VC
Pump VC/HT
Gears HT/VC
Coffee grinder C/A Vacuum cleaner /
brush
Water route D Descaler (Saeco)
Hot water / steam valve VC/R
Water drain (valve pin) C Fat solvent / brush
6.1. Repair plan
R = Replace C = Clean VC = Visual check
HT = Hearing test D = Descale A = Adjust