Specifications

D1. Diagnostics menu
Settings
system settings
D1.2.2A. System setting
grounds settings
grounds limit (13) Maximum dregs
actual grounds
+/- (counts from 13
upwards)
+/- (1-26) Dreg counter
warning grounds (8) +/- (1-13)
If this value is the same as the
dreg counter then “empty dreg
drawer” appears
Coffee can still be dispensed The
counter is reset when emptied
delay reset
grounds
+/- (1-100) 50 = 5 sec
The time the dreg counter
should be reset to when the dreg
drawer has been removed
heater settings
cup temperature (78) +/- (70-85) Coffee temperature (in the cup)
coffee temp
temp.active (112) +/- (80-140)
Boiler temp. when coffee is
dispensed
temp.inactive (105) +/- (80-140)
Boiler temp. when coffee is not
being dispensed
steam
temperature
temp.active (145) +/- 130-150) Boiler temp. when steam is used
temp.inactive (120) +/-(130-150) no function
hot water
temperature
(90) +/- (70-120)
Boiler temp. when hot water is
dispensed
grinder settings medium dose (80-100)/(auto dose) +/- (50-150)
Grinder pulse with medium
dose From V..........autodose
(automatic setting)
owmetre settings hot water owrate +/- (13-18) (18) Flow rate
D1.2.2B
service date
on/off
(ON takes over
the current date)
Date setting service