Use and Care Manual

GASCONVERSION:
Conversion from Natural Gas to Liquid Propane (LP) or vice versa may only be performed by the factory or its authorized service agent.
CLEANING-
NOTE: It is important to check the machine daily. Checking the machine regularly can avoid serious accidents. Stop using if user feels
that there are some problems with the unit. Check the condition of the machine before and after using every day.
1. Before cleaning, turn off all gas valves.
2. Please clean the burners and drip tray of all debris and spillage daily. A complete cleaning every day will ensure a good service
and extend the service life of the unit.
3. Clean the stainless steel surface with warm soapy water every day and rinse it completely. Do not saturate range with
water, excessive water will cause operational issues. During cleaning, do not clean the stainless steel surface with
abrasive detergent, brush or scraper etc. The residual iron scale may cause rusting.
4. Do not clean the surface with chlorine cleanser (bleach, dish detergent, hydrochloric acid etc.). Do not clean the
floor where the device locates with corrosive substance.
5. Do not change the burner shutter settings.
6. Accumulation of substances containing salt or acidic ingredients, e.g. vinegar, lemon juice, spices, salt etc. can cause
corrosion. Thus, please do not allow these substances to have long contact with the unit.
7. After cleaning, ensure that the ports of the burners are open and clear of any residue.
8. Clean cast iron top grates with a mild soap and water solution. Rinse thoroughly and dry with a clean, water-absorbent towel.
Immediately after drying, season grates lightly with liquid vegetable oil. After seasoning, replace grates on range and turn burners
on LOW, allow grates to heat for 15 minutes before using pots or pans on the range top. Failure to season grates after cleaning will
result in rust.
9. If unit will sit idle for a significant period of time, please turn off the gas valve upstream the device.
TROUBLESHOOTING
Problem
PossibleCauses
Solution
The pilot flame can’t be ignited
The gas pressure is too low
Adjust the relieve valve to
increase pressure
The pilot flame can’t be ignited
The nozzle is clogged
Unclog the nozzle
The pilot flame can’t be ignited
Connection of the thermocouple is
loose
Tighten the thermocouple
The pilot flame can’t be ignited
The thermocouple is defective
Replace the thermocouple
The pilot flame can’t be ignited
The gas control valve is
malfunctioning
Replace the gas control valve
Problem
PossibleCauses
Solution
The pilot flame is on but the
main burner can’t be ignited
The gas pressure is too low
Adjust the relieve valve to
increase pressure