User's Manual
EMS User Manual-v2.0.0
Accounting
This being a broadcast solution, there is no per user accounting that is applicable in the case of EMS.
Fault Monitoring
Faults originated at the device are available as Alarm Notifications on EMS. Based on the Alarms
Configuration for a given type of Alarm, an alarm can be acknowledged automatically. Details of the
alarms supported by the system are mentioned in the table below.
Table 1: Alarms Definitions
Copyright Saankhya Labs Private Ltd, Bangalore 5
ID
Module
Alarm Type
Default Level
comment
0
EMS
EMS Internal Alarm
Warning
1
DVBS2
Backhaul Link Status Alarm
Critical
Backhaul BER > 2e-6 for 3mins
2
DVBS2
Backhaul Data Failure Alarm
Warning
MPE Section Errors, RTP
Sequence Errors etc.
3
STLTP
STL-TP Link status Alarm
Minor
STL-TP packet error > x for 3
mins
4
GPS
GPS Lock Alarm
Critical
GPS Lock != Lock
5
ATSC3P0
ATSC3.0 Modulation Config Error
Alarm
Critical
L1 Signaling != Valid
6
GLOBAL
BRH power status Alarm
Critical
BRH Power Status == OFF
7
GLOBAL
BRH BIST status Alarm
Critical
Built In Self-Test Status == FAIL
8
GLOBAL
BRH Temperature Threshold Alarm
Critical
Temperature > Threshold value
9
GPS
GPS Timing Sync Alarm
Warning
GPS time < EPOCH time
10
GLOBAL
Device Rebooted Alarm
Info
Device Rebooted