User's Manual
R&D / Automotive Electronics
Title Remote Keyless Entry System Specification Spec. No. DPE-AE-RK019912S
Written by
Rev. No.
A0
Date 24 . July. 2007 Page
23 / 23
2
thermal shock
The part shall be subjected to 5 thermal cycles. One
cycle shall be consisted of :
+110℃
-40℃
1 hr 1hr
Using 2 shuttle chambers with a 2 minutes minimum
transition.
3
storage
The part shall be subjected the uninterrupted storage
schedule as below;
-40℃:70hours
+110℃:118hours
4
temperature.
and humidity
cycle test
The part shall be subjected to 5 cycles. One cycle shall
be consisted of::
+100℃
+37℃,98%RH
-40℃
12hrs 6hrs 6hrs
Perform a functional check of each unit every 12 hours
current consumption should be
in ±20% compared with initial
ones .The SPL(min.):100dB.
The tone should be normal