G
THERMASGARD
®
ATM 2
Rev. 2017 - V12 GB
Calibratable outside temperature measuring transducer
THERMASGARD
®
ATM 2
with eight switchable measuring ranges, internal or remote
sensor, continuous output, terminal box enclosure made of impact-resistant plastic, enclosure cover with quick-locking screws, with or without
optional display. For the detection of outside temperatures, temperatures in wet room areas, e.g. for installation on outside walls, in cold storage
buildings and greenhouses, in the industrial sector and in agriculture. Installation in outdoor areas preferably at the north side of a building or in a
protected place. In case of direct sun irradiation, the sunshade and ball game protection
WS 01
(accessories) or the device variant with the installed
sunshade
SS 02
(available on request) must be used. These outdoor sensors are factory-calibrated. Adjustment ⁄ fine adjustment by the user is
possible (zero point offset is adjustable).
TECHNICAL DATA
Power supply: 24 V AC ⁄ DC (± 10 %) for U variant
15...36 V DC for I variant,
depending on working resistance, residual ripple stabilised ± 0.3 V
Working resistance: R
a
(ohm) = (U
b
-14 V) ⁄ 0.02 A for I variant
Load resistance: R
L
> 5 kOhm for U variant
Power consumption: < 1.0 VA ⁄ 24 V DC; < 2.2 VA ⁄ 24 V AC
Sensor: Pt1000, DIN EN 60751, class B, (Perfect Sensor Protection)
sensor inside external stainless steel sensor tube, 1.4571, V4A
Measuring ranges:
multi-range switching with 8 switchable measuring ranges,
see table (other ranges optional)
operating range –30...+70 °C
with manual zero point correction (± 10 K)
Deviation, temperature: ± 0.2 K at +25 °C
Output: 0 - 10 V or 4...20 mA
Ambient temperature: measuring transducer –30...+70 °C
Connection type: 2- or 3-wire connection
Process connection: by screws
Enclosure: plastic, material polyamide,
30 % glass-globe-reinforced,
with quick-locking screws,
(slotted ⁄ Phillips head combination),
colour traffic white (similar to RAL 9016),
enclosure cover for display is transparent!
Enclosure dimensions: 72 x 64 x 37.8 mm (Tyr 1 without display)
72 x 64 x 43.3 mm (Tyr 1 with display)
Cable gland: M 16 x 1.5, including strain relief, exchangeable,
max. inner diameter 10.4 mm
Electrical connection: 0.14 - 1.5 mm² via terminal screws
Humidity: < 95 % r. H., non-precipitating air
Protection class: III (according to EN 60 730)
Protection type:
IP 65
(according to EN 60 529)
Standards: CE conformity,
electromagnetic compatibility according to
EN 61326, according to EMC directive 2014 ⁄ 30 ⁄ EU
Optional: Two-line
display with illumination
,
cutout approx. 36 x 15 mm (W x H), for displaying the
ACTUAL temperature
and the
internal diagnostics
(measuring range exceeded, measuring range not
reached, sensor breakage, sensor short circuit)
THERMASGARD
®
ATM 2
– Outside temperature ⁄ wet room temperature measuring transducers
Type ⁄ WG01 Sensor Output
Display Item No.
ATM 2 - I IP 65, I - variant
ATM2-I Pt1000 4...20 mA 1101-1142-0009-900
ATM2-I_DISPLAY Pt1000 4...20 mA ■ 1101-1142-2009-900
ATM 2 - U IP 65, U - variant
ATM2-U Pt1000 0 - 10 V 1101-1141-0009-900
ATM2-U_DISPLAY Pt1000 0 - 10 V ■ 1101-1141-2009-900
Extra charge: Other ranges optional
with sunshade
SS 02
on request
Display
Measuring range
exceeded
Standard
Measuring range
not reached
Sensor
breakage
Sensor
short circuit