User Manual

14
If you make changes to the conguration settings, and then click
"Cancel", you will be asked if you want to save your changes.
Select "Yes" to return to the previous screen so you can save your
changes, or "No" to exit without saving.
Coil Conguration
Coil Saturation Constant is a value used to calculate the dwell time
for charging the coil. It is used in conjunction with battery voltage
to determine the dwell time. When the battery voltage is low, the
dwell time is increased to compensate.
The coil conguration is calculated automatically by the IST Ignition
System and cannot be changed at the dealer user level.
Information
To view the IST Ignition Module Information screen, click on the
tool bar button.
The IST Ignition Module Information screen displays the historical
data stored in the IST Ignition Module.
There are 4 dierent data display tabs available:
Engine Usage
Maximums
Rev Limit
Version
You can also reset this information with the "Do Rebuild" button.
WARNING! USING THIS FUNCTION WILL VOID ANY REMAINING
S&S® ENGINE WARRANTY!
Engine Usage
To view the "Engine Usage" information, click on the tool
bar button and select the "Engine Usage" tab.
Runtime and Revolutions
This shows the number of hours an engine has run, along with the
total number of revolutions and engine starts since it was new or
rebuilt. The "Since Rebuild/New" data is reset to zero when the "Do
Rebuild" function is performed.
Click on the "OK" button to close this screen.