Specifications

65IP Camera and Encoder Software Manual
SECTION 3: SETUP CONFIGURATION
1. Click the Reboot button on the webpage.
2. Wait until the system restarts (about 1 minute).
3. Access the webpage to see if the display is normal.
If your system repeatedly reboots in Safety Mode after performing the steps above:
Repeated reboots in Safety Mode indicate that an element of the device rmware is damaged. Perform
the following steps to recover the rmware.
1. Start IPAdmin Tool and discover the device. The device entry will indicate that the encoder or IP
camera is in Safety Mode.
2. Right-click the device entry and select the Update menu.
3. After completing a rmware update, examine the webpage to verify that the device booted normally.
4.4 Limited functions under Safety Mode
Safey Mode loads only the essential executable modules and disables the normal operation of the device.
The functions available and those with limited capability include:
Available functions:
IP change by IPAdmin Tool
Scanning by IPAdmin Tool
Searched by UPnP program
Functions with limited capability:
RTSP or HTTP streaming
Event messages or alarming
Recognition of HTTP API commands