Specifications
54
www.sc-black.com
SECTION 3: SETUP CONFIGURATION
DI Resource type
For the DI accessories attached to your device, select either RELAY or VOLTAGE. Both DI#1 and DI#2
must be the same type.
DIDOstatus
This status display shows the current state of the DI and DO accessories.
DO Control
Use these four buttons to click DO#1 and DO#2 ON and OFF. The status of each device is shown in the
DIDO Status frame.
Friendly name
Enter whatever friendly name for the DI and DO that you prefer. This feature is useful when DI and/or DO
is activated, especially if there are multiple device servers managed by your application program.
DI Trigger type
Select the DI device trigger type for the device installed (normally open (NO) or normally closed (NC)).
DI Interval between triggers
The DI interval between triggers sets the detection time interval for the event publisher. If “0” is specied,
the device reports an event every time a DI event is sensed. If “10” is specied, the device must sense
multiple DIs events within 10 seconds before reporting the event.
DO Working time
The DO working time sets the duration the DO is activated. If “0” is entered, the DO remains active until it
is manually turned off. If “10” is entered, DO is activated for 10 seconds.
Apply and Reset
After making conguration changes, click Apply to save the settings, or click Reset to revert to the
previous settings.
Example
DI#1 and DO#1 are congured to sense and report the same event. The DI#1 trigger type is Normal
Open. Suddenly DI#1 is triggered by any kind of event.
Expected Response: The status of DO#1 will change from OFF to ON if the default setting is OFF. The
status of DI#1 will change from OPEN to CLOSE.