Specifications
51IP Camera and Encoder Software Manual
SECTION 3: SETUP CONFIGURATION
Event Publisher: vsignal
Operation: Blink
Time Out: 5
Option: Turn on the LED of vsignal. Select When video signal loss is detected.
Basic conguration
SCBlack devices have different positions for their LEDs. Refer to the applicable user manual for more
information.
1. Select Enable LED.
2. Select LED1 and/or LED2.
3. Select the Event Publisher from the dropdown list to associate with the LED.
4. Select the Operation of each LED, Blink or On.
5. Select the Time Out (duration of reporting). The LED can be lit from 1 ~ 5 seconds, or on
permanently.
6. If you are conguring an LED to report DSP load (dspload), temperature, and video signal loss
(vsignal), and/or heartbeat, additional conguration options are available:
— Set the dspload limits to: When setting the DSP limit and the Publisher selected is dspload,
the associated LED will operate as congured in the Location section when the DSP load
exceeds the limit.
— Set the temperature limits to: When setting the temperature limit(s) and the Publisher
selected is temperature, the associated LED will operate as congured in the Location section
when the temperature is outside the limit(s).
— Turn on the LED of vsignal: Select either “When video signal loss is detected” or “When
video signal is normal”. If a Publisher selected is vsignal, the associated LED will operate as
congured in the Location section when the option is satised.
— Turn on the LED of Heartbeat: Select either “When heartbeat status is watchdog” or “When
heartbeat status is normal”. If a Publisher selected is heartbeat, the associated LED will