User Manual

ionTig 200 Pulse PFC
Copyright © Mundaka Welding & Gases, Inc.
25
4.5 Operation Environment
Height above sea level is below 1000m.
Operation temperature range:-10
0
C+40
0
C.
Relative humidity is below 90 % (20
0
C).
Preferably site the machine some angles above the floor level, the maximum angle does not exceed
15
0
.
Protect the machine against heavy rain or in hot circumstance against direct sunshine.
The content of dust, acid, corrosive gas in the surrounding air or substance cannot exceed normal
standard.
Take care that there is sufficient ventilation during welding. There is at least 30cm free distance
between the machine and wall.
4.6 Operation Notices
Read §1 carefully before attempting to use this equipment.
Connect the ground wire with the machine directly, and refer to §3.5.
In case closing the power switch, no-load voltage may be exported. Do not touch the output electrode
with any part of your body.
Before operation, no concerned people should be left. Do not watch the arc in unprotected eyes.
Ensure good ventilation of the machine to improve duty ratio.
273
2.5
810
2.5
110
125
1416
1214
56
325
2.5
810
2.5
120
140
1416
1214
56
Notice: the above parameters originate fromWelding DictionaryP167, Volume 1 of Edition 2.