4.5 Operation Environment
● Height above sea level is below 1000m.
● Operation temperature range:-10
0
C~+40
0
C.
● Relative humidity is below 90 % (20
0
C).
● Preferably site the machine some angles above the floor level, the maximum angle does not exceed
15
0
.
● Protect the machine against heavy rain or in hot circumstance against direct sunshine.
● The content of dust, acid, corrosive gas in the surrounding air or substance cannot exceed normal
standard.
● Take care that there is sufficient ventilation during welding. There is at least 30cm free distance
between the machine and wall.
4.6 Operation Notices
● Read §1 carefully before attempting to use this equipment.
● Connect the ground wire with the machine directly, and refer to §3.5.
● In case closing the power switch, no-load voltage may be exported. Do not touch the output electrode
with any part of your body.
● Before operation, no concerned people should be left. Do not watch the arc in unprotected eyes.
● Ensure good ventilation of the machine to improve duty ratio.
273
2.5
8~10
2.5
110~
125
14~16
12~14
5~6
325
2.5
8~10
2.5
120~
140
14~16
12~14
5~6
Notice: the above parameters originate from《Welding Dictionary》P167, Volume 1 of Edition 2.