User Manual

ionTig 200 Pulse PFC
Copyright © Mundaka Welding & Gases, Inc.
19
NOTE:
Only the Iw of TIG or the welding current of MMA can be adjust when welding.
4.3 Argon Arc Welding Operation
4.3.1 TIG welding (4T operation)
The start current and crater current can be pre-set. This function can compensate the possible
crater that appears at the beginning and end of the welding. Thus, 4T is suitable for the welding of
medium thickness plates.
Pulsed TIG long welding (4T):
t( s)
0
I( A)
Loosen the
switch
t1 t5
t7
Striking success
Stop arc
t3
t4
Base current setting
value
t2 t6
Loosen the
switch
Repress down the
switch
Start
current
Crater
current
Welding current (peak
current) setting value
Press and hold the
welding gun switch
Introduction
0 Press and hold the gun switch, Electromagnetic gas valve is turned on. The
shielding gas starts to flow;
0t1 Pre flow time, adjustment range of pre flow time :0.0~2.0S;
t1 Striking success, adjustment range of start current: 5~180A200A;
t2 Loosen the gun switch, the output current slopes up from start current; if the output
pulse function is turned on, the output current is pulsed;
t2t3 Output current slopes up to the setting current value; adjustment range of up slope
time 0~10.0S ;
t3t4 Welding process. During this period, the gun switch is loosen;
Note: If the output pulse function is turned on, the output current is pulsed. If the output pulse
function is turned off, the output current is the welding current(Iw);