User Manual

ionTig 200 Pulse PFC
Copyright © Mundaka Welding & Gases, Inc.
13
the right position. When the machine gets to the destination, it needs to be fixed up to avoid gliding.
When using forklift, its arm length must be long enough to reach the outside so as to ensure lifting
safely.
The movement may result in the potential danger or substantive hazard, so please make sure
that the machine is on the safe position before using it.
3.4 Power supply input connection
ionTig 200 Pulse PFC welding machines’ power supply connects to 220V.
When the power supply voltage is over the safe work voltage, there are over voltage and under
voltage protection inside the welder, the alarm light will on, at the same time, the current output will
be cut off.
If the power supply voltage continually goes beyond the safe work voltage range, it will shorten the
welder life-span. The below measures can be used:
Change the power supply input net. Such as, connect the welder with the stable power supply
voltage of distributor;
Induce the machines using power supply in the same time;
Set the voltage stabilization device in the front of power cable input.
3.5 Polarity Connection (MMA)
MMA (DC): Choosing the connection of DCEN or DCEP according to the different electrodes.
Please refer to the electrode manual.
WTL
workpiec
e
electrode
DC POSITIVE
CONNECTION
Welding holder
TP-315
WTL
workpiec
e
Welding holder
electrode
DC NEGATIVE
CONNECTION
TP-315
TIG 200
DC PULSE
TIG 200
DC PULSE