User Manual
ionMig 200 PFC
Copyright © Mundaka Welding & Gases, Inc.
24
been put correctly in place, please correct; If you can't correct or fix the knob ,
please replace immediately;
If the switch is not flexible or it can't be put correctly in place, please replace
immediately; Please get in touch with maintenance service department if there
are no accessories.
After turn-on power, watch/listen to that whether the arc welding machine
has shaking, whistle calling or peculiar smell. If there is one of the above
problems, find out the reason to get rid of; if you can't find out the reason,
Please contact local this area agent or the branch company.
Observe that whether the display value of LED is intact. If the display
number is not intact, please replace the damaged LED. If it still doesn’t work,
please maintain or replace the display PCB.
Observe that whether the min/max value on LED accords with the set value.
If there is any difference and it has affected the normal welding craft, please
adjust it.
Checkup that Whether fan is damaged and is normal to rotate or control. If
the fan is damaged, please change immediately. If the fan does not rotate after
the arc welding machine is overheated , observe that whether there is something
blocked in the blade, if it is blocked, please get rid of ; If the fan does not rotate
after getting rid of the above problems, you can poke the blade by the rotation
direction of fan. If the fan rotates normally, the start capacity should be
replaced; If not, change the fan.
Observe that whether the fast connector is loose or overheated. If the arc
welding machine has the above problems, it should be fastened or changed.
Observe that Whether the current output cable is damaged. If it is damaged, it
should be wrapped up, insulated or changed.
Monthly
examination
Using the dry compressed air to clear the inside of arc welding machine.
Especially for clearing up the dusts on radiator, main voltage transformer,
inductance, IGBT module, the fast recover diode and PCB, etc.
Check up the bolt in arc welding machine, if it is loose, please screw down it.
If it is skid, please replace. If it is rusty, please erase rust on bolt to ensure it
works well.
Quarter-
yearly
examination
Whether the actual current accords with the displaying value. If they did not
accord, they should be regulated. The actual current value can be measured by
the adjusted plier-type ampere meter.
Yearly
Measure the insulating impedance among the main circuit, PCB and case, if it