User Manual
ionMig 200 PFC
Copyright © Mundaka Welding & Gases, Inc.
23
normal standard.
▲ Take care that there is sufficient ventilation during welding. There is at least 30cm free
distance between the machine and wall.
▲ Preferable site the machine some angles above the floor level, the maximum angle does
not exceed 15℃.
▲ Protect the machine against heavy rain or in hot circumstance against direct sunshine.
▲ The content of dust, acid, corrosive gas in the surrounding air or substance cannot exceed
normal standard.
▲ Take care that there is sufficient ventilation during welding. There is at least 30cm free
distance between the machine and wall.
5 Maintenance & Troubleshooting
5.1 Maintenance
In order to guarantee that arc welding machine works high-efficiently and in safety, it must be
maintained regularly. Let customers understand the maintenance methods and means of arc
welding machine more , enable customers to carry on simple examination and safeguarding by
oneself, try one's best to reduce the fault rate and repair times of arc welding machine, so as to
lengthen service life of arc welding machine .Maintenance items in detail are in the following table.
● Warning: For safety while maintaining the machine, please shut off the supply power and wait for 5
minutes, until capacity voltage already drop to safe voltage 36V.
Date
Maintenance items
Daily
examination
Observe that whether panel knob and switch in the front and at the back of
arc welding machine are flexible and put correctly in place. If the knob has not