3.1 Parameters
Model
Parameters
MultiMIG200PFC
MultiMIG250PFC
Input VoltageV
1-110±10%
1-220±10%
1-110±10%
1-220±10%
Input CurrentA
MIG 31.7
MMA 32
TIG 19
MIG 26
MMA 30
TIG 19.5
MIG 43
MMA 37
TIG 32
MIG 43
MMA 44
TIG 36
Input PowerKW
MIG 3.4
MMA 3.5
TIG 2.1
MIG 26
MMA 30
TIG 19.5
MIG 4.7
MMA 4.0
TIG 3.5
MIG 9.4
MMA 9.6
TIG 7.9
Welding CurrentA
MIG 40-140
MMA 10-110
TIG 10-150
MIG 40-200
MMA 10-200
TIG 10-200
MIG 40-160
MMA 10-130
TIG 10-130
MIG 40-250
MMA 10-250
TIG 10-250
No-load VoltageV
66
66
66
66
Duty cycle40℃)
MIG 140A30%
MMA 110A30%
TIG 150A40%
MIG 200A30%
MMA 200A25%
TIG 200A35%
MIG 160A35%
MMA 130A30%
TIG 140A35%
MIG 250A35%
MMA 250A30%
TIG 250A35%
Diameter(mm)
Fe 0.60.80.91.0 1.2 Ss 0.80.91.0 1.2
Protection class
IP23
Insulation class
H
Dimensionsmm
550*214*395
635*240*430
WeightKg
12.5
25
Note: The above parameters are subject to change with the improvement of