Cut Sheet

Please note: All measurements are rounded to
the second decimal place.
Distributed by
S-5!® Warning! Please use this product responsibly!
Products are protected by multiple U.S. and foreign patents. Visit the website at www.S-5.com for
complete information on patents and trademarks. For maximum holding strength, setscrews should
be tensioned and re-tensioned as the seam material compresses. Clamp setscrew tension should be
veried using a calibrated torque wrench between 160 and 180 inch pounds when used on 22ga steel,
and between 130 and 150 inch pounds for all other metals and thinner gauges of steel. Consult the S-5!
website at www.S-5.com for published data regarding holding strength.
Copyright 2015, Metal Roof Innovations, Ltd. S-5! products are patent protected.
S-5! aggressively protects its patents, trademarks, and copyrights. Version 052115.
The strength of the S-5-U clamp is in its simple design. The patented
setscrews will slightly dimple the metal seam material but not pierce it—
leaving the roof manufacturer's warranty intact.
S-5-U Mini Clamp
S-5-U Clamp
Note: Install both
setscrews on same
side of clamp.
1.50"
(38.00 mm)
0.90"
(23.00 mm)
0.40"
(10.00 mm)
1.50"
(38.00 mm)
M8 hole
located 1/2" (13.00 mm)
from edge of part
0.54"
(14.00 mm)
1.50"
(38.00 mm)
0.90"
(23.00 mm)
0.40"
(10.00 mm)
1.50"
(38.00 mm)
M8 holes centered
on part
0.54"
(14.00 mm)
1.18"
(30.00 mm)
2.00"
(51.00 mm)
Example Proles
For horizontal seams under 0.65", do not use this clamp. Visit
www.S-5.com for more detailed information and proper
clamp usage.
The S-5-U and S-5-U Mini clamps are each furnished with
the hardware shown to the right. Each box also includes
a bit tip for tightening setscrews using an electric screw
gun. A structural aluminum attachment clamp, the S-5-U
is compatible with most common metal roong materials
excluding copper. All included hardware is stainless
steel. Please visit www.S-5.com for more information
including CAD details, metallurgical compatibilities and
specications.
The S-5-U clamp has been tested for load-to-failure results
on most major brands and proles of standing seam
roong. The independent lab test data found at
www.S-5.com can be used for load-critical designs and
applications. S-5!® holding strength is unmatched in the
industry.