Installation Manual
- 39 -
1.4.5.1 ALARM OUT SETUP 
The 1.4.5.1 ALARM OUT SETUP screen defines the Input – Trigger – Response relationships with the 
various sensors and reporting devices connected to the MDVR. The ALARM OUT SETUP screen adds the 
ability to add ALARM and ALARM logging responses to the other criteria set within the individual Sensor 
and Device screens. 
ALM SOURCE
(ASOURCE) 
The input to trigger the ALM (Alarm) Output 
ALM OUTPUT 
(OUTPUT) 
The output path to a Sensor Output 
LOG 
Select whether the detected Alarm is also logged as an ALARM 
SENS IN 
Select one of 8 Sensor Inputs (SENS IN) 
TEMP IN 
(DISK BTP) 
Select one of 5 Temperature inputs (TEMP IN 1 is standard. All others require 
optional external sensor devices. 
SPEED 
Monitors High and Low speed settings in 1.4.2.1 SPEED SETTINGS 
G SENSOR 
Monitors X, Y, Z settings in 1.4.3.1 G SENSOR SETUP 
VIDEO LOSS 
Monitors Video Loss (Camera malfunction) 
MOTION DET 
Monitors movement or light changes sensed by the 1.4.6.1 MOTION DETECTION 
SETUP 
HW ERROR 
Monitors factory set criteria for the detection of hardware level errors 
GPS ERROR 
Monitors factory set criteria for the detection of GPS Module signal reception errors 
Action Bar Keys (Select, then press ENTER): 
SAVE 
To save and activate the new settings 
SETUP MENU 1.4 
''ALARM'
ALARM  1.4.5 
'ALARM OUT'
ALARM OUT 
SETUP 1.4.5.1 
Mobilemule™ 