Instruction Manual

- 40 -
1.4.5.1 ALARM OUT SETUP
The 1.4.5.1 ALARM OUT SETUP screen defines the Input Trigger Response relationships with the
various sensors and reporting devices connected to the MDVR. The ALARM OUT SETUP screen adds the
ability to add ALARM and ALARM logging responses to the other criteria set within the individual Sensor
and Device screens.
ALM SOURCE
The input to trigger the ALM (Alarm) Output
ALM OUTPUT
The output path to a Sensor Output
LOG
Select whether the detected Alarm is also logged as an ALARM
IO
Select one of 8 Sensor Inputs (IO1-8)
DISK TEMP
Hard disk temperature alarm.
SPEED
Monitors High and Low speed settings in 1.4.2.1 SPEED SETTINGS
G -SENSOR
Monitors X, Y, Z settings in 1.4.3.1 G SENSOR SETUP
VIDEO LOSS
Monitors Video Loss (Camera malfunction)
MOTION
Monitors movement or light changes sensed by the 1.4.6.1 MOTION DETECTION
SETUP
HW ERROR
Monitors factory set criteria for the detection of hardware level errors
GPS ERROR
Monitors factory set criteria for the detection of GPS Module signal reception errors
Action Bar Keys (Select, then press ENTER):
SUMMARY
To move to the 1.4.5.1.1 ALARM OUT SUMMARY PAGE to view a list of the
Input Trigger Response relationships currently setup
SAVE
To save and activate the new settings
MASTER MENU 1.4
''BASIC'
BASIC MENU 1.4.5
'ALARMS'
ALARM SETUP
1.4.5.1
'ALARM OUT'
Mobilemule™