Instruction Manual
- 11 -
DEVICE START-UP 
The  following  assumes  the  User  has  confirmed  the  DVR  is  correctly  installed  according  to  the 
manufacturers installation instructions and is correctly configured for use: 
Pre-check before Startup: 
LCD MONITOR 
Connected to either the rear I/O Cable Monitor Connector or the A/V Jack on 
the Front Panel 
SECURITY PANEL 
Closed 
POWER SOURCE 
Connected and MDVR STATUS PANEL PWR indicator (blue) is lit 
Startup Sequence: 
CHECK POWER 
The PWR indicator (blue) will be lit on the front Status Panel to show the 
MDVR is receiving power. If the Monitor is powered by the MDVR is may 
not display anything until the 0.0 LOADING PAGE appears 
INSERT KEY 
Insert key into Security Lock located on the front panel 
POWER ON 
Turn the key counterclockwise 90
0
 from the UNLOCK position 
P.O.S.T.
Pre-Operation  System Test.  It  is  an  automatic  and  required  comprehensive 
test of the operational status during startup of the MDVR requiring about 48 
seconds to complete. 
LOADING SCREEN 
The Loading Screen will be displayed during the P.O.S.T. If not, then check 
if Monitor is power On and the correct viewing channel set 
START UP VIEW 
The Startup Screen will be displayed. The camera view(s) will be as set in the 
last setup of the MDVR 
CHECK STATUS 
Use the IRC to verify the operational status of the MDVR: 
INFO Press to view 1.8.1 SYSTEM INFO PG 1 OF 2 
NEXT Select, then: 
ENTER Press to view PG 2. 