Verifying that Calibration was
Successful
The nal mandatory step for calibrating your inView360 HD
AVM system is to ensure that the calibration was successful�
1. Navigate to or back to the Live screen� If you are in any
of the calibration windows, click the Back button
and/or the ESC button until you see the Live screen�
2. Congure the vehicle to Full Screen Top view�
• If the Green Driver/View button is installed, click the button to nd the Full
Screen Top view�
3. Inspect the 360 degree image in the monitor.
a. Ensure that each of the four mats looks like one contiguous mat with minimal distortion�
b. Have someone walk around the vehicle and ensure that you can see at least their feet at all times as they walk
around the vehicle, especially in the corners� (The corners are the transition points where the camera images are
stitched together.)
c. Test drive in a controlled environment (a parking lot, for example) at a low speed to ensure that objects ow
smoothly through the transitions�
NOTE: The 6 views
Clicking the Green button cycles through the following 6 views: Top
+ Left, Top + Right, Top + Front, Top + Back, Full Top, and a split view
that contains Left, Right, Front, and Back�
• If the Green Driver/View button is not installed, then refer to the Conguring the Default View section of the
InView 360 HD AVM Conguration Guide (700-1217).
NOTE: Addressing Issues with the Transitions
If you observe any issues with the transitions, you might have to do one of the following:
• Adjust the blend angles
• Try manual calibration (see the InView 360 HD Calibration Guide, document number 700-1216)