Technical data
Technical documentation 
Technical documentation
STZS ed 06/03 
6 
ZEUS SUPERIOR
- CIRCULATOR  
This operates on the primary circuit return and is 
located on the brass header assembly of the electric 
three ways valve. 
It is connected to the monobloc and exchanger by 
means of threaded connecting pipes. 
The pumps used differ according to boiler output (see 
head - flow graph). 
The body is equipped with a threaded fitting which 
on the21 and 24 versions is used for the connection of 
the expansion vessel and of the automatic vent valve,  
while on the 27 version is used for the directly 
connection of the automatic air vent. 
.
21 and 24 versions 
 27 version 
- FLOW HEAD GRAPH 
The curve that represents the relation between the 
flow rate and the available head depends on system 
bypass adjustment which, depending on its position, 
gives the system greater or less head. 
The graphs are refereed to the pump operating at top 
speed with: 
 - A = Bypass disconnected (screw fully tightened) 
 -  B = Standard bypass adjustment (screw tightened 
by 4.5 turns with respect to fully-tightened position) 
 - C = Bypass open (screw fully loose) 
 ZEUS 21 Superior 
 ZEUS 24 Superior 
 ZEUS 27 Superior 
- PRIMARY HEAT EXCHANGER 
This is a water-gas blade type exchanger with copper pipes 
and fins at the outlet of which an NTC heating probe (5) is 
located. 
The size differs according to boiler heat output.
The four pipes passing through the exchanger are connected 
in parallel (1) two by two, to reduce flow resistance to the 
utmost and provide a greater available head. 
It is connected to the pump flow and to the primary circuit 
flow by means of coupling pipes (2) with O.R. seal (4). 
These are secured by means of special forks (3). 