Technical data
Technical documentation 
Technical documentation
STZS ed 06/03 
18 
ZEUS SUPERIOR
ELECTRICAL CIRCUIT 
CAR Remote control 
CZ  Control xone unitt 
DL1  Central heating operation LED 
DL2  D.h.w. operation LED 
DL3 Flame LED 
E1/E2 Ignition electrodes 
E3 Detection electrode 
EP  Gaudium Magnum solenoid valve 
F Fuse  
IG Main switch 
IP  Gaudium Magnum switch 
LP  Gaudium Magnum operating 
indicator 
MOD Modulation coil 
MP Circulator 
MV Fan 
NB  D.h.w. NTC sensor 
NE External sensor (optional) 
NR  Central heating NTC sensor 
P1  Room thermostat jumper 
PU1 Reset button 
SP  Pump pressure switch 
SV  Flue pressure switch 
TA Room thermostat 
TP  Max flow limit thermostat 
TS Overheat. safety 
thermostat 
VD  Electric three-way valve 
V/G Gas valve
The electric circuit is interlocked with a microprocessor electronic board that controls boiler functions. 
The control and safety devices work in part at mains voltage and in part at low voltage. 
230 V AC CIRCUIT 
SAFETY DEVICES AND CONTROLS 
Detection electrode (E3)  
This detects ignition of the burner by whose flame it is invested. 
It is connected to the detection circuit of the ignition unit. 
Fuse 
This interrupts power to the circuit when amp draw is over 3.15 A. 
It is fitted on the modulation board. 
Fuse 
3.15 A 250 V 
“Gaudium 
 Magnum” switch 
(IP) 
Enables the operation of the Gaudium Magnum solenoid valve (EP), 
which is supplied by the maximum flow limit thermostat (TP). 
0  - solenoid valve closed (not supplied) 
  - solenoid valve enabled (supplied by the closing of the 
  maximum flow limit thermsostat switch) (TP) 
2-contacts switch