Technical data

Technical documentation
Technical documentation
STZS ed 06/03
18
ZEUS SUPERIOR
ELECTRICAL CIRCUIT
CAR Remote control
CZ Control xone unitt
DL1 Central heating operation LED
DL2 D.h.w. operation LED
DL3 Flame LED
E1/E2 Ignition electrodes
E3 Detection electrode
EP Gaudium Magnum solenoid valve
F Fuse
IG Main switch
IP Gaudium Magnum switch
LP Gaudium Magnum operating
indicator
MOD Modulation coil
MP Circulator
MV Fan
NB D.h.w. NTC sensor
NE External sensor (optional)
NR Central heating NTC sensor
P1 Room thermostat jumper
PU1 Reset button
SP Pump pressure switch
SV Flue pressure switch
TA Room thermostat
TP Max flow limit thermostat
TS Overheat. safety
thermostat
VD Electric three-way valve
V/G Gas valve
The electric circuit is interlocked with a microprocessor electronic board that controls boiler functions.
The control and safety devices work in part at mains voltage and in part at low voltage.
230 V AC CIRCUIT
SAFETY DEVICES AND CONTROLS
Detection electrode (E3)
This detects ignition of the burner by whose flame it is invested.
It is connected to the detection circuit of the ignition unit.
Fuse
This interrupts power to the circuit when amp draw is over 3.15 A.
It is fitted on the modulation board.
Fuse
3.15 A 250 V
“Gaudium
Magnum” switch
(IP)
Enables the operation of the Gaudium Magnum solenoid valve (EP),
which is supplied by the maximum flow limit thermostat (TP).
0 - solenoid valve closed (not supplied)
- solenoid valve enabled (supplied by the closing of the
maximum flow limit thermsostat switch) (TP)
2-contacts switch