INSTALLATION INSTRUCTIONS FOR 9000 SERIES AIR CONDITIONERS CLIMATISEURS SÉRIE 9000 INSTRUCTIONS D’INSTALLATION
TABLE OF CONTENTS I. II. III. IV. V. VI. VII. VIII. IX. X. General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air Conditioning Sizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Selecting An Installation Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installing The Roof Top Unit . . . . . . . . . . .
II. AIR CONDITIONING SIZING The ability of an air conditioner to provide a comfortable environment for the consumer is dependent upon the following conditions. As a general rule, air supplied (discharge air) from the air conditioner will be 15 to 20 degrees cooler than the air entering (return air) the ceiling assemblies bottom air grilles. Air conditioners are rated primarily by their ability to remove heat.
Once the location for your air conditioner has been determined (See Section III), a reinforced and framed roof hole opening must be provided (may use existing vent hole). Before cutting into the vehicle roof, verify that the cutting action will clear all structural members and crossbeams. Additionally, the location of any inner roof plumbing and electrical supplies must be considered. A.
FIGURE 2 If the roof of the vehicle is sloped (not level) such that the roof top air conditioner cannot be mounted within the maximum allowable degree deviations, an exterior leveling shim will need to be added to make the roof top air conditioner level. A typical leveling shim is shown in Figure 3. E. 5 After the mounting hole area is properly prepared, remove the carton and shipping pads from the roof top air conditioner. Carefully lift the unit to the top of the vehicle.
V. SECURING THE AIR CONDITIONER TO THE ROOF A mounting frame is supplied with the ceiling assembly. Follow the steps below to secure the air conditioner to the roof. Refer to Figure 4. D. A. Locate the air conditioner mount gasket over the 14" to 15" square opening in the roof. B. Install the ceiling assembly mount frame using the four bolts found with the ceiling assembly. C.
VI. ELECTRICAL WIRING ROUTING 115 VAC WIRING THIS COULD RESULT IN PINCHING THROUGH THE PLASTIC WIRE INSULATION AND CAUSE SHORTING OR “HOT” WIRES TO GROUND (SHOCK HAZARD). THE CLAMP IS INTENDED FOR STRAIN RELIEF OF THE WIRES. SLIGHT PRESSURE IS USUALLY SUFFICIENT TO ACCOMPLISH THIS. Following RV Products high voltage wiring specifications and all local and national electrical codes, route the roof top unit 115 VAC supply wiring from its power source to the wirebox. High Voltage Wiring Specifications 1. 2.
The Following Two Sections Pertain Only To 8000 Series Ceiling Assemblies VII. INSTALLING THE CEILING ASSEMBLY (8000 SERIES) G. Place metal flange in discharge duct opening, trapping fabric between it and the ceiling assembly (See Figure 5). H. Pull fabric tight. This will minimize material bunching inside the discharge duct collar. Make sure that you have properly matched the roof top air conditioner and interior ceiling assembly.
FIGURE 5 9
VIII. COMPLETING THE INSTALLATION (8000 SERIES) To complete the installation and system checkout requirements, the following steps must be performed. A. B. C. Check the thermostat probe position. Make sure the thermostat probe is routed through the holding guide and is not touching any metal surface. THIS ENTIRE STEP “B” IS NOT REQUIRED ON “COOLING ONLY” CEILING ASSEMBLIES.
thermostat side of the ceiling assembly. If installing an Elect-A-Heat equipped ceiling assembly, plug the heater cord into the 2 position receptacle (See Figure 11). F. G. H. by the control box shield. Control box shield is properly installed when the two holes in the shield are aligned with the two screw holes in the ceiling assembly chute (See Figure 11). Install the provided cable clamp in the 7/8" dia. hole on the back of the metal field wiring box.
FIGURE 13 FIGURE 14 X. COMPLETING THE INSTALLATION (9000 SERIES) A. Make sure the non-allergenic filters are properly positioned in the ceiling grille. B. Install the ceiling grille by positioning on the bottom of the shroud and engaging the two 1/4 turn fasteners. C. Turn the selector switch to OFF position. D. Turn ON the power supply to the roof top air conditioner. E.
TABLE DES MATIÈRES I. II. III. IV. V. VI. VII. VIII. IX. X. Renseignements généraux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration du climatiseur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Choix d’un emplacement pour l’installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation de l’appareil sur le toit . .
II. CONFIGURATION DU CLIMATISEUR La capacité du climatiseur de fournir au client un environnement confortable dépend des conditions suivantes. Par exemple, si l’air qui entre dans le climatiseur (l’air recyclé) est de 80 degrés Fahrenheit (27 degrés Celsius) l’air d’alimentation (air de décharge) dans le véhicule sera de 60 à 65 degrés Fahrenheit (15 à 18 degrés Celsius).
IV. INSTALLATION DE L’APPAREIL SUR LE TOIT plafond. Si cette ouverture est recouverte de tapis, il pourrait y avoir des accrocs. Après avoir une ouverture à la bonne taille pour le toit et le plafond intérieur, prévoyez une structure de support encadrée entre le dessus du toit extérieur et le plafond intérieur. La structure encadrée renforcée doit respecter les directives suivantes : DANGER CHOC ÉLECTRIQUE COUPEZ TOUT COURANT AU VÉHICULE AVANT TOUT TRAVAIL DE COUPE AU VÉHICULE.
E. Après avoir préparé correctement la région de l’ouverture d’installation, retirez le carton et les blocs d’expédition du climatiseur de toit. Soulevez délicatement l’appareil sur le dessus du véhicule. N’utilisez pas le carénage extérieur de plastique pour soulever. Placez l’appareil sur l’ouverture d’installation. L’extrémité pointue (nez) du carénage doit faire face à l’avant du véhicule.
NORMALEMENT D’UNE LÉGÈRE PRESSION. DANGER DANGER DE CHOC ÉLECTRIQUE SI VOUS UTILISEZ DES CÂBLES AUTRES QUE LES CÂBLES NON-MÉTALLIQUES COMME CONDUCTEURS D’ALIMENTATION, VOUS DEVEZ UTILISER LES PINCES OU CONNECTEURS DE RÉDUCTION DE TENSION APPROPRIÉS.
K. Prenez le conduit électrique du climatiseur de toit et raccordez-le à l’arrière de la boîte de commande du thermostat. Assurez-vous que le côté « nervuré » de la prise est alignée et jumelée au côté « nervuré » de la connexion de la boîte de commande du thermostat. N’UTILISEZ PAS TROP DE FORCE et assurez-vous que les tenons s’encliquettent en place (voir la figure 6). L. Retirez le couvercle de la boîte de commande du sélecteur (une vis).
B. Retirez la grille et les filtres du montage de plafond. C. Si l’option Elect-A-Heat est choisie, retirez le montage de l’appareil de chauffage du guide du montage de plafond. Placez le montage de l’appareil de chauffage dans l’ouverture de l’air de reprise du climatiseur tel qu’indiqué à la figure 10. La fixation de l’appareil de chauffage doit être installée sur l’extrusion du plateau de métal et placée entre le plateau et le plateau de vidange de plastique (voir la figure 10).
X. FIN DE L’INSTALLATION (SÉRIE 9000) A. Assurez-vous que les filtres non allergènes sont bien installés dans la grille du plafond. B. Installez la grille du plafond en la plaçant au bas du carénage et en fermant les deux attaches de 1/4 de tour. C. Placez le sélecteur à la position OFF (arrêt). D. Mettez le climatiseur de toit en marche. E. Vérification du système - RV Products fabrique une vaste gamme de climatiseurs de toit qui incorpore différentes fonctions d’exploitation du produit.
RV Products A Division of Airxcel, Inc. P.O.