12. BY-FLOW RESTRICTOR REPLACEMENT
1. Remove top panel.
2. Remove Section C (See Figure 11).
3. Remove outdoor blower. Follow steps 1-4 in Outdoor
Blower Motor Removal Section.
4. Be certain at this point that the refrigerant charge has
been removed from the system/systems being
serviced.
5.
Remove clamps holding restrictor in place
(See #17, Figure 12).
6. Unbraze by-flow restrictor from points 16. Make note
of plumbing locations for new restrictor. Must be
installed in same manner. (Note to protect any wiring
that could come into contact with the torch flame or
heated copper lines.)
Note: Upon reassembly, the references made on
Figures 11 and 12 shall be used for proper
reassembly. The assemblies shall be
secured with wire ties in order to prevent