Service manual

12
10. INDOOR BLOWER MOTOR
REMOVAL
1. Remove indoor blower access panel.
2. Disconnect wiring from motor terminal block and
capacitor.
3. Remove 4 screws from venturi (See #1, Figure 7).
4. Remove 3 screws from motor mount bracket
(See #2, Figure 7).
5. Remove motor assembly from scroll.
6. Remove blower wheel and motor mounting bracket.
Note: Upon reassembly, the references made on
Figures 7 and 8 shall be used for proper
reassembly.
SIDE VIEW
Section 1. Position motor with terminal block parallel to motor mount leg opposite motor clamp. Assemble motor mount into
scroll in orientation shown.
Section 2.
Torque nut to 65 in. lbs. min.
Section 3.
Ground wire terminal assemblies between screw head and washer.
Section 4.
Motor rotation wires to be connected: Yellow to Yellow and Orange to Orange.
Section 5.
Alternate capacitor: 1499-546
Section 6.
Bundle the rotation and capacitor wires up and wire tie together.