11. CHECKOUT
1. Before engaging power to any system, insure the
following:
A) All tools have been removed from the
equipment.
B) All wiring is attached, routed and properly
secured.
C) All panels (both mechanical and electrical)
are in place.
D) The thermostat system switch is placed into
the “OFF” position and fan switch is placed
in the “Auto” position.
E) All co-workers have been warned that the
equipment is being energized.
2. System wiring may be checked by referring to the
wiring diagram located on the back of the wiring box
door.
3. Before beginning the checkout procedure, thoroughly
read the instructions in either the thermostat
installation instructions or in the owners manual
provided with this product.
Keep in mind that the wall thermostat provides a
3 minute delay between off and on cycles.
There is also a 30 second delay between 1
st
and 2
nd
stage cooling. This is to prevent both compressors
from starting simultaneously. To insure that the
thermostat calls for both 1
st
and 2
nd
stage cooling,
verify that the cool setpoint is well below actual
indoor temperature.
4. After complying with steps 1 through 3, engage
power to all systems and begin checkout procedure.
5. Test each thermostat function, such as fan modes,
heat modes and cool modes to insure proper
operation.