How to Guide

TECHNICAL DATA
V2100 SYSTEM ENAMEL AEROSOL
Form: GDH-682
Rev.: 021115
2
.PRODUCT APPLICATION (cont.) .
SURFACE PREPARATION (cont.)
STEEL: Hand tool (SSPC-SP-2) or power tool (SSPC-SP-3)
clean to remove loose rust, mill scale, and deteriorated previous
coatings. For best results, use Red Primer on sound rusted or
clean metal before the application of a finish coat or intermediate
primer.
PREVIOUSLY COATED: Previously coated surfaces must be
sound and in good condition. Smooth, hard, or glossy finishes
should be scarified by sanding to create a surface profile.
GALVANIZED STEEL: New galvanized steel may contain a
surface wax or oil from the fabricator. This must be removed with
Pure Strength
®
Cleaner/Degreaser (#3599402), commercial
detergent or other suitable cleaner. NOTE: Only the
Galvanizing Compounds are to be used on galvanized steel. Do
not use any other of the 1600 System Primers or Finish Colors.
WEATHERED GALVANIZED STEEL: Remove loose rust and
stains by hand tool (SSPC-SP-2) or power tool (SSPC-SP-3)
prior to application of the Cold Galvanizing Compound.
.PRODUCT APPLICATION (cont.) .
APPLICATION
Use when temperature is above 5F (1C) and humidity is
below 85% to ensure proper drying. Surface temperature must
be between 50-100°F (10-3C).
Use primer on bare or rusted surfaces. Do not use any primer
with V2116838 High Temperature Aluminum, V2176838 High
Temperature Black, V2117838 Bright Galvanizing Compound or
V2185838 Cold Galvanizing Compound.
Protect surrounding surfaces from overspray. Overspray can
carry a significant distance. Shake can for one minute after
mixing ball is heard. Hold can 10-14 inches from surface. Apply
several light coats a few minutes apart to avoid drips and runs.
DRY & RECOAT TIMES
Recoat within 1 hour or after 24 hours. allow more time in cooler
temperatures.
CLEAN-UP
Wipe off tip before storing. Clean-up wet paint with xylene or
mineral spirits. Properly discard empty container. Do not burn or
place in trash compactor. Empty container can be recycled.
CLOGGING
If the valve clogs, twist and pull off spray tip and rinse in a solvent
such as mineral spirits. Do not insert any object into can valve
opening.