Technical Specifications

INGESTION
Low in toxicity, induce vomiting only if large amounts of material are ingested, and otherwise do not induce vomiting. In
either case consult with a physician.
5. Fire-Fighting Measures
SUITABLE EXTINGUISHING MEDIA
Foam, alcohol foam, co2, dry chemical, water fog
SPECIAL FIRE FIGHTING PROCEDURES
None known.
6. Accidental release measures
SPILL AND LEAK PROCEDURES
Wear respirator and protective clothing. Shut o the source at the leak. Remove excess with vacuum truck and take up the
remainder with an absorbent such as clay and place in disposal containers. Flush area with water to remove residue.
7. Handling and Storage
STORAGE TEMPERATURE
Minimum: 0 C (32º F)
Maximum: 50 C (122º F)
STORAGE PERIOD
6 months in unopened containers
HANDLING / STORAGE PRECAUTIONS
Store in a cool dry place. Seal all partially used containers. Wash with soap and water before eating, drinking, smoking
or using toilet facilities. Mixed materials contain the hazards of all the components, therefore, read the msds’s of all the
components prior to using material. Properly label all containers .
FURTHER INFO ON STORAGE CONDITIONS
Avoid all skin contact. Avoid breathing vapors generated from the material. Observe conditions of good general hygiene
and safe working practices. Contaminated leather articles can not be cleaned and must be discarded if contaminated with
this product. Wash all contaminated clothing prior to the reuse thereof.
8. Exposure Controls/ Personal Protection
Country specic exposure limits have not been established or are not applicable.
INDUSTRIAL HYGIENE/VENTILATION MEASURES
General dilution and local exhaust as necessary to control airborne vapors, mists, dusts and thermal decomposition
products below appropriate airborne concentration standards/guidelines. Curing ovens must be ventilated to prevent the
build up of explosive atmospheres and to prevent o gases from entering the work place.
RESPIRATORY PROTECTION
Use a niosh approved respirator as required to prevent over exposure to vapor in accordance with 29 cfr 1910.134.
General exhaust is usually sucient in lieu of niosh respirator.