SDS

Date Printed: 5/30/2019
STEPS TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED: Remove all sources of ignition, ventilate area and remove with
inert absorbent and non-sparking tools. Dispose of according to local, state (provincial) and federal regulations. Do not incinerate
closed containers. Ventilate area, isolate spilled material, and remove with inert absorbent. Dispose of contaminated absorbent,
container, and unused contents in accordance with local, state, and federal regulations.
7. Handling and Storage
HANDLING: Wash thoroughly after handling. Wash hands before eating. Remove contaminated clothing and launder before reuse.
Use only with adequate ventilation. Follow all SDS and label precautions even after container is emptied because it may retain
product residues. Avoid breathing fumes, vapors, or mist. Avoid contact with eyes, skin and clothing.
STORAGE: Store in a dry, well ventilated place. Keep container tightly closed when not in use. Keep containers tightly closed.
Isolate from heat, electrical equipment, sparks and open flame. Do not store above 120 ° F. Store large quantities in buildings
designed and protected for storage of NFPA Class II combustible liquids. Keep away from heat, sparks, flame and sources of
ignition. Avoid excess heat. Product should be stored in tightly sealed containers and protected from heat, moisture, and foreign
materials.
Advice on Safe Handling of Combustible Dust: No Information
8. Exposure Controls / Personal Protection
Chemical Name CAS-No.
Weight %
Less Than
ACGIH TLV-
TWA
ACGIH TLV-
STEL
OSHA PEL-TWA
OSHA PEL-
CEILING
Hydrotreated Light Distillate 64742-47-8 50.0 N.E. N.E. N.E. N.E.
Titanium Dioxide 13463-67-7 5.0 10 mg/m3 N.E. 15 mg/m3 N.E.
Methyl Ethyl Ketoxime 96-29-7 1.0 10 ppm N.E. N.E. N.E.
Stoddard Solvent 8052-41-3 1.0 100 ppm N.E. 500 ppm N.E.
Ethylbenzene 100-41-4 1.0 20 ppm N.E. 100 ppm N.E.
Naphtha, Hydrotreated Heavy 64742-48-9 1.0 N.E. N.E. N.E. N.E.
Cobalt 2-Ethylhexanoate 136-52-7 1.0 N.E. N.E. N.E. N.E.
PERSONAL PROTECTION
ENGINEERING CONTROLS: Use process enclosures, local exhaust ventilation, or other engineering controls to control airborne
levels below recommended exposure limits. Prevent build-up of vapors by opening all doors and windows to achieve cross-
ventilation.
RESPIRATORY PROTECTION: A respiratory protection program that meets OSHA 1910.134 and ANSI Z88.2 requirements must be
followed whenever workplace conditions warrant a respirator's use. A NIOSH/MSHA approved air purifying respirator with an organic
vapor cartridge or canister may be permissible under certain circumstances where airborne concentrations are expected to exceed
exposure limits.
Protection provided by air purifying respirators is limited. Use a positive pressure air supplied respirator if there is any potential for an
uncontrolled release, exposure levels are not known, or in any other circumstances where air purifying respirators may not provide
adequate protection.
SKIN PROTECTION: Use gloves to prevent prolonged skin contact. Nitrile or Neoprene gloves may afford adequate skin protection.
EYE PROTECTION: Use safety eyewear designed to protect against splash of liquids.
OTHER PROTECTIVE EQUIPMENT: Refer to safety supervisor or industrial hygienist for further guidance regarding types of
personal protective equipment and their applications.
HYGIENIC PRACTICES: Wash thoroughly with soap and water before eating, drinking or smoking. Remove contaminated clothing
immediately and launder before reuse.
Engineering Measures for Combustible Dust: No Information
Page 3 / 6